Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Blood ; 138(20): 1917-1927, 2021 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-34792573

RESUMO

Biomedical applications of deep learning algorithms rely on large expert annotated data sets. The classification of bone marrow (BM) cell cytomorphology, an important cornerstone of hematological diagnosis, is still done manually thousands of times every day because of a lack of data sets and trained models. We applied convolutional neural networks (CNNs) to a large data set of 171 374 microscopic cytological images taken from BM smears from 945 patients diagnosed with a variety of hematological diseases. The data set is the largest expert-annotated pool of BM cytology images available in the literature. It allows us to train high-quality classifiers of leukocyte cytomorphology that identify a wide range of diagnostically relevant cell species with high precision and recall. Our CNNs outcompete previous feature-based approaches and provide a proof-of-concept for the classification problem of single BM cells. This study is a step toward automated evaluation of BM cell morphology using state-of-the-art image-classification algorithms. The underlying data set represents an educational resource, as well as a reference for future artificial intelligence-based approaches to BM cytomorphology.


Assuntos
Células da Medula Óssea/patologia , Doenças Hematológicas/diagnóstico , Redes Neurais de Computação , Células da Medula Óssea/citologia , Diferenciação Celular , Doenças Hematológicas/patologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Microscopia/métodos
2.
Int J Comput Assist Radiol Surg ; 11(3): 397-405, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26233623

RESUMO

PURPOSE: Inhomogeneous illumination often causes significant shading and vignetting effects in images captured by an endoscope. Most of the established shading correction methods are designed for gray-level images. Only few papers have been published about how to compensate for shading in color images. For endoscopic images with a distinct red coloring, these methods tend to produce color artifacts. METHOD: A color shading correction algorithm for endoscopic images is proposed. Principal component analysis is used to calculate an appropriate estimate of the shading effect so that a one-channel shading correction can be applied without producing undesired artifacts. RESULTS: The proposed method is compared to established YUV and HSV color-conversion-based approaches. It produces superior results both on simulated and on real endoscopic images. Example images of using the proposed shading correction for endoscopic image mosaicking are presented. CONCLUSION: A new method for shading correction is presented which is tailored to images with distinct coloring. It is beneficial for the visual impression and further image analysis tasks.


Assuntos
Algoritmos , Imagens de Fantasmas , Ureteroscopia/métodos , Bexiga Urinária/diagnóstico por imagem , Cor , Humanos , Interpretação de Imagem Assistida por Computador , Iluminação , Reconhecimento Automatizado de Padrão , Radiografia , Reprodutibilidade dos Testes , Técnica de Subtração
4.
Anticancer Res ; 32(12): 5221-6, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23225419

RESUMO

BACKGROUND: A prototype system for computer-assisted colposcopic diagnosis (CAD) currently achieves a high level of accuracy of 80% (sensitivity 85%, specificity 75%) for the automatic assessment of colposcopic images. This pilot study investigated whether this type of CAD system is, in principle, capable of influencing the quality of the examiner's assessment. MATERIALS AND METHODS: In this observer study, 24 digitized colposcopic images from patients attending a dysplasia clinic were assessed by 90 participants. All participants had attended a colposcopy training workshop so that they acquired the same basic information and skills. RESULTS: Wide variation was seen among the non-experts, in contrast to the experts. An overall improvement in diagnostic accuracy was noted when the CAD system was used (non-experts: sensitivity 78%, specificity 70%; experts: sensitivity 74%, specificity 70%). CONCLUSION: The CAD system may serve as an aid in the further diagnosis of cervical intraepithelial neoplasia, and has the potential to improve the diagnostic process.


Assuntos
Colposcopia/métodos , Diagnóstico por Computador/métodos , Displasia do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/diagnóstico , Colposcopia/educação , Colposcopia/normas , Diagnóstico por Computador/normas , Feminino , Humanos , Variações Dependentes do Observador , Projetos Piloto , Sensibilidade e Especificidade , Neoplasias do Colo do Útero/patologia , Displasia do Colo do Útero/patologia
5.
Acta Cytol ; 56(5): 554-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23075899

RESUMO

PURPOSE: Diagnosis of cervical intraepithelial neoplasia (CIN) is currently based on the histological result of an aiming biopsy. This preliminary study investigated whether diagnostics for CIN can potentially be improved using semiautomatic colposcopic image analysis. METHODS: 198 women with unremarkable or abnormal smears underwent colposcopy examinations. 375 regions of interest (ROIs) were manually marked on digital screen shots of the streaming documentation, which we provided during our colposcopic examinations (39 normal findings, 41 CIN I, and 118 CIN II-III). These ROIs were classified into two groups (211 regions with normal findings and CIN I, and 164 regions with CIN II-III). We developed a prototypical computer-assisted diagnostic (CAD) device based on image-processing methods to automatically characterize the color, texture, and granulation of the ROIs. RESULTS: Using n-fold cross-validation, the CAD system achieved a maximum diagnostic accuracy of 80% (sensitivity 85% and specificity 75%) corresponding to a correct assignment of abnormal or unremarkable findings. CONCLUSIONS: The CAD system may be able to play a supportive role in the further diagnosis of CIN, potentially paving the way for new and enhanced developments in colposcopy-based diagnosis.


Assuntos
Colposcopia/métodos , Diagnóstico por Computador/métodos , Displasia do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/diagnóstico , Adulto , Idoso , Colo do Útero/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Esfregaço Vaginal
6.
Breast Cancer Res ; 14(2): R59, 2012 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-22490545

RESUMO

INTRODUCTION: Although mammographic density is an established risk factor for breast cancer, its use is limited in clinical practice because of a lack of automated and standardized measurement methods. The aims of this study were to evaluate a variety of automated texture features in mammograms as risk factors for breast cancer and to compare them with the percentage mammographic density (PMD) by using a case-control study design. METHODS: A case-control study including 864 cases and 418 controls was analyzed automatically. Four hundred seventy features were explored as possible risk factors for breast cancer. These included statistical features, moment-based features, spectral-energy features, and form-based features. An elaborate variable selection process using logistic regression analyses was performed to identify those features that were associated with case-control status. In addition, PMD was assessed and included in the regression model. RESULTS: Of the 470 image-analysis features explored, 46 remained in the final logistic regression model. An area under the curve of 0.79, with an odds ratio per standard deviation change of 2.88 (95% CI, 2.28 to 3.65), was obtained with validation data. Adding the PMD did not improve the final model. CONCLUSIONS: Using texture features to predict the risk of breast cancer appears feasible. PMD did not show any additional value in this study. With regard to the features assessed, most of the analysis tools appeared to reflect mammographic density, although some features did not correlate with PMD. It remains to be investigated in larger case-control studies whether these features can contribute to increased prediction accuracy.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Idoso , Área Sob a Curva , Neoplasias da Mama/patologia , Estudos de Casos e Controles , Feminino , Humanos , Modelos Logísticos , Pessoa de Meia-Idade , Razão de Chances , Fatores de Risco
7.
Arch Gynecol Obstet ; 285(6): 1663-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22262493

RESUMO

PURPOSE: To compare diagnostic performance and interobserver variability in a group of 36 examiners, with four different levels of experience. METHODS: Nine junior trainees, eight level I senior trainees, 11 level II senior gynecologists, and eight level III expert sonologists classified 105 ultrasound images of adnexal masses into three subgroups of ovarian lesions (malignancies, functional cysts, and dermoid cysts). RESULTS: The level III sonologists obtained the best diagnostic results together with the lowest interobserver variability (κ = 0.70, SD = 0.04). They achieved significantly better results in comparison with the junior trainees and also the senior trainees (κ = 0.51, SD = 0.12, p < 0.001; and κ = 0.51, SD = 0.09, p < 0.001). Differences between level III sonologists and the group of level II observers did not reach statistical significance (κ = 0.65, SD = 0.09, p = 0.70). There were no significant differences between senior and junior trainees (p = 1.0) and both groups achieved a significantly poorer diagnostic performance in comparison with the level II observers (p < 0.01 and p < 0.01). For all observers, the largest differences were seen for classifying malignancies, the best results for classifying functional cysts, and the poorest for evaluating dermoid cysts. CONCLUSIONS: Diagnostic performance of pattern recognition significantly improves with an increasing level of experience, emphasizing the importance of standardized ultrasound training programs with supervision by experts.


Assuntos
Doenças Ovarianas/patologia , Ovário/patologia , Reconhecimento Visual de Modelos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Tamanho do Órgão , Doenças Ovarianas/diagnóstico por imagem , Ovário/diagnóstico por imagem , Ultrassonografia , Adulto Jovem
8.
Artigo em Inglês | MEDLINE | ID: mdl-19965015

RESUMO

Flexible endoscopes based on fiber bundles are still widely used despite the recent success of so-called tipchip endoscopes. This is partly due to the costs and that for extremely thin diameters (below 3 mm) there are still only fiberscopes available. Due to the inevitable artifacts caused by the transition from the fiber bundles to the sensor chip, image and texture analysis algorithms are severely handicapped. Therefore, texture-based computer-assisted diagnosis (CAD) systems could not be used in such domains without image preprocessing. We describe a CAD system approach that includes an image filtering algorithm to remove the fiber image artifacts first and then applies conventional color texture algorithms that have been applied to other endoscopic disciplines in the past. The concept is evaluated on an image database with artificially rendered fiber artifacts so that ground truth information is available.


Assuntos
Diagnóstico por Computador/métodos , Tecnologia de Fibra Óptica/métodos , Processamento de Imagem Assistida por Computador/instrumentação , Algoritmos , Artefatos , Simulação por Computador , Computadores , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Fibras Ópticas , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Software
9.
IEEE Trans Biomed Eng ; 53(10): 2035-46, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17019868

RESUMO

Modern techniques for medical diagnostics and therapy in keyhole surgery scenarios as well as technical inspection make use of flexible endoscopes. Their characteristic bendable image conductor consists of a very limited number of coated fibers, which leads to so-called comb structure. This effect has a negative impact on further image processing steps such as feature tracking because these overlaid image structures are wrongly detected as image features. With respect to these tasks, we propose an automatic approach to generate optimal spectral filter masks for enhancement of fiberscopic images. We apply the Nyquist-Shannon sampling theorem to the spectrum of fiberscopically acquired images to obtain parameters for optimal filter mask calculation. This can be done automatically and independently of scale and resolution of the image conductor as well as type and resolution of the image sensor. We designed and verified simple rotation invariant masks as well as star-shaped rotation variant masks that contain information about orientation between the fiberscope and sensor. A subjective survey among experts between different modes of filtering certified the best results to the adapted star-shaped mask for high-quality glass fiberscopes. We furthermore define an objective metric to evaluate the results of different filter approaches, which verifies the results of the subjective survey. The proposed approach enables the automated reduction of fiberscopic comb structure. It is adaptive to arbitrary endoscope and sensor combinations. The results give the prospect of a large field of possible applications to reduce fiberscopic structure both for visual optimization in clinical environments and for further digital imaging tasks.


Assuntos
Inteligência Artificial , Endoscópios , Endoscopia/métodos , Tecnologia de Fibra Óptica/instrumentação , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Algoritmos , Desenho de Equipamento , Análise de Falha de Equipamento , Tecnologia de Fibra Óptica/métodos , Imageamento Tridimensional/métodos , Armazenamento e Recuperação da Informação/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
10.
IEEE Trans Biomed Eng ; 53(2): 254-65, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16485754

RESUMO

This paper presents a new spectral approach to color correction for medical image analysis applications. Linear estimation with regularization by a constrained principal eigenvector method is used for calibration of the camera system and estimation of the illumination spectrum while spectral surface reflectivities are determined by Wiener inverse estimation. Nonlinear devices are handled by piecewise linear interpolation and any linear color preprocessing inside the camera is explicitly modeled. All measurement and estimation processes are combined into a spectral calibration framework for practical application in computer-assisted image analysis. The novelty of our approach lies in the generalization of the image formation model allowing for linear preprocessing inside the camera system. Such transforms would lead to erroneous results with positivity constraint based algorithms or a monochromator based measurement. We provide experimental results from a comprehensive set of reference measurements acquired with a video endoscopy system for gastroscopic application.


Assuntos
Algoritmos , Artefatos , Colorimetria/métodos , Gastroscopia/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Gravação em Vídeo/métodos , Colorimetria/instrumentação , Gastroscópios , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Gravação em Vídeo/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...